Tropic Marin Block Nickel (Balance Block solution)
trace
Manufacturer data
As an Amazon Associate we earn from qualifying purchases. Buying through these links costs you nothing extra and helps keep the app free.
What one dose does
PARAMETER
1 ml / 100 L
Manganese
+1 ppb
Iron
+0.75 ppb
Boron
+0.0004 ppm
To raise manganese by 0.5 ppb in 100 L: 0.5 ml.
Maker’s daily maximum: 4 ml per 100 L (4 ml for 100 L).
How it’s used
Daily dose; standard start 0.05 ml per 100 L/day (lab calculator). Retest the indicator element (nickel, target 3 ug/L) by ICP and scale the dose; the calculator caps adjustments at 10x the start dose.
Cautions
• Max 4 ml per 100 L per day
• Store cool and dark
• Adjust the daily dose from ICP results of the indicator element (Tropic Marin lab block calculator)
Sources
Art. no. 28894. Concentrations and 2 ml/100 L effects from the product page; start dose and target from lab.tropic-marin.com block calculator (adjustment factor = 1.4 x (target/measured) - 0.4, ratio clamped 0.3-2.5; warning at 5x start dose). Also carries NI, CO (not tracked by the app).