Triton Lab Manganese (Mn)
trace
Partly derived
As an Amazon Associate we earn from qualifying purchases. Buying through these links costs you nothing extra and helps keep the app free.
What one dose does
PARAMETER
1 ml / 100 L
Manganese
+1 ppb
To raise manganese by 0.5 ppb in 100 L: 0.5 ml.
Maker’s daily maximum: 0.2 ml per 100 L (0.2 ml for 100 L).
How it’s used
Dose only per the DOSE tab of a TRITON ICP-OES test (correction + maintenance dose). Total dose = (target - current) x L / potency; never exceed the daily max, split larger corrections over days; dose into high flow, 5 min apart from other elements; re-test by ICP ~1 month later.
Cautions
• dangerous if dosed incorrectly
Sources
Max daily conflict: trace calculator 0.2 ml/100 L, element-mix 0.68 ml/100 L; lower used.
triton.de/en/products/supplements
triton.de/en/toolkit/trace-element-supplementation-calculator
triton.de/typo3conf/ext/dstemplate/Resources/Public/Relaunch2025/js/pages/trace-element-dosing-calculator.js
triton.de/en/toolkit/element-mix-calculator